RV Refrigerator Repair - Problem Solving
No Cooling on any fuel source
This situation indicates a problem with the cooling unit,
itself. Follow the steps below to determine the cause.
For an explanation of how the cooling unit operates see
how it works.
Testing the Cooling Unit
Testing by " Feel "
For this method of testing the only tools required are your
hands! CAUTION: some of the components may be HOT! Be
careful!
If a cooling unit is operating properly, there should be
approximately the same amount of heat in the middle sections of
the boiler and absorber.
Cooling unit blockages
When a cooling unit malfunctions due to a blockage, the
boiler section may be too hot to touch and the absorber will be
relatively cool. Any blockage reduces the free flow of the
solutions and will inhibit or completely prevent proper
operation.
A blockage is caused when the fridge is operated in an off
level condition. The heat that is generated by the propane
flame or the electric heating element is the force that
initiates the cycling of the solutions inside the cooling unit.
This action is similar to the familiar coffee percolator where
the water is lifted by the heat and flows by gravity down over
the coffee grounds.
The refrigerator depends on gravity to move the solutions
through the system once the heat source has lifted the
solutions to the top of the cooling unit. The passages that the
solution must travel through have only a slight slope to them
and any off-level condition will hinder this gravity flow.
Parking on a hill, with your refer running while you go off to
lunch, starts the degradation of the system and every time you
do this, it adds up. There is no way to reverse this
problem.
What happens in this situation, is that the solution in the
cooling unit gets overheated, and a component of this solution
crystallizes and becomes solid particles that float around and
lodge where they're not supposed to.
Tipping the refer upside down, may or may not, dislodge the
particles, but they are still in there and will (sooner or
later) plug things up again.
You have two choices ... replace the cooling unit (new or
recharged) or replace the entire refrigerator.
A new refer or a new cooling unit, comes with a one year
warranty. In my area, a rebuilt cooling unit comes with a five
year warranty - figure that one out!
Leaking Cooling Unit
If the boiler is warm and the absorber is hot this indicates
that a leak has developed and the hydrogen gas has escaped. The
liquid ammonia does not change to a vapor without the hydrogen
gas atmosphere and circulates as a liquid. A strong ammonia
smell is a definate sign of a leak. The cooling unit must be
replaced or re-built.
There is a chemical called sodium chromate in the solution
that circulates inside the cooling unit. It is there to prevent
the ammonia/hydrogen/water solution from corroding the steel
tubing. If a leak developes, this chemical changes from a
liquid state to a powder in the presence of air. A yellow
residue on the outside of the cooling unit indicates a
leak.
Advanced testing methods
Dometic recommends the following method for testing the
cooling unit:
1. Make sure the unit is level.
2. Hook up the 110 VAC element directly to a 110 volt
source, in effect bypassing the thermostat and control systems.
To do this, locate the two white wires coming from the 110 volt
heating element. The heating element is located in the
cylindrical tin casing surrounding the burner flu, and is
accessible through the removable panel on the side of the
casing. If you have a three way refer there should be two
elements side by side. The 12 volt element can be identified by
noting the way the wires are connected. The 12 volt element has
one wire connected directly to the element and the other wire
connects with a spade type of terminal. The 110 volt element
has both wires connected directly to the element. Also, if you
fully remove the elements, the voltage will be stamped on the
casing.
Disconnect the two wires at the terminal block and connect
these wires directly to a 110 volt source. If you are not
comfortable or sure about what you are doing, then this test is
best left to your RV Technician.
3. Place a thermometer in a glass of water and place in the
food compartment. It is important to use the glass of water for
this test as it equalizes the temperature reading.
4. After 12 hours the temperature should be 43 deg. F or
less.
5. After 24 hours the temperature should be between the low
20's to high 30's maximum. If these temperatures are not
reached and maintained, then the the cooling unit is faulty and
should be replaced or rebuilt.
LPG Flame Outage Problem
The first steps to undertake are to clean the flue, the
burner tube and the orifice. Remove the rear access cover on
the outside of the coach. On the right lower side of the
refrigerator, there is a tin cover which you remove to access
the burner. The flue, or chimney, is located right above the
burner flame. Often, a flakey rust colored residue falls from
the flue and clogs up the burner ( this is a result of
combustion and is a normal occurrence). This residue will also
interfere with the sensor probe and flame outage will
result.

Use compressed air to blow out the flue and the surrounding
area. Remove the screw holding the small tab that holds the
thermocouple in place. The thermocouple is a narrow rod with
the end that sticks into the burner flame. Pull out the
thermocouple to access the two screws that hold the burner
assembly in place.
Remove the burner tube and soak it in alcohol for 15
minutes, then let it air dry.
The orifice is located just to the left of the burner tube and
is a brass colored nut with a very tiny hole in it. Remove this
a let it soak in alcohol also. Do not probe or poke anything
into the orifice to clean it - this will drastically affect the
flame characteristics and will render the orifice useless. Once
soaked and dried, you should be able to hold it up to a light
source and see the light shining through the orifice
opening.
Re assemble every thing and light the burner flame. A normal
flame will be a "hard blue" color with no yellow tip, and will
emit a slight roaring sound. If you still have a flame outage
problem then the electrical circuitry is most likely the
cause.
The Electric Heating Element
The electric heating element supplies the neccessary heat
for refer operation on shore power. It is located at the rear
of the refer as shown here (under the cover marked #6).

The element can be checked with an ohm-meter. Be sure to
disconnect the 110 volt power cord and the 12 volt supply
before working on the unit. On three way refrigerators there
will be two heating elements - on a two way model, there will
be only one. Note: some older models had a combination 110 volt
and 12 volt element in one casing.
Locate and disconnect the wires leading to the element. With
the multi-meter set on ohms reading, check the resistance of
the element.

A zero reading indicates an internal short inside the
element - an infinite reading shows an open circuit - in either
case, replace the element. The correct reading varies from
model to model.
|